LGEE Control Area Forced Outages

UNIQUEID DATEOUT ANTICIPATEDDATEIN DATEIN EVENT REASON DESCRIPTION
2013L000001972 12/21/2013 22:25:00 12/29/2017 09:25:00 12/29/2017 09:25:00 WT-138KV BUS TIE TO WT-3842 - TR4 LOCKOUT - AUTO SECTIONALIZED (CLOSING OUT OLD REQUEST -- NO ACTUAL OUTAGE)
2017L000015399 09/18/2017 06:00:00 02/20/2018 16:46:00 02/20/2018 16:46:00 MT-138KV TR 1 BUS TO MT-69KV TR 1 TRANS - REPAIR AFTER OUTAGE
2017K000016485 12/27/2017 10:00:00 12/27/2017 16:47:00 12/27/2017 16:47:00 448-305 TO 187-0428 - Outwood 448 Station outage
2017L000016493 12/28/2017 10:35:00 12/28/2017 11:35:00 12/28/2017 10:47:00 CRS-3821 TO CRC-3821 - Cane Run Sw-Cane Run CT 3821 relayed out during distribution load swap and subsequent fault and relay operation. DCC indicates CR-1420 14KV tie switch flashed over during an open operation. DCC advised there was no 138kv overbuild on 14KV distribution pole where fault occurred.
2018K000016508 01/02/2018 05:00:00 01/02/2018 10:47:00 01/02/2018 10:47:00 034-654 TO 034-654 - Relay'd, remote end reclosed, 034-654 CLOSE control FAILED.
2018K000016506 01/02/2018 05:00:00 01/02/2018 12:00:00 01/02/2018 12:00:00 021-608 TO N21-825 - Repair 704L disconnect
2018L000016507 01/02/2018 06:36:00 01/02/2018 19:58:00 01/02/2018 19:58:00 SH-6626 TO CRS-6626 - Line Relayed out
2018K000016525 01/03/2018 02:29:00 01/03/2018 12:08:00 01/03/2018 12:03:00 066-602 TO 066-602 - repair capacitor after lockout
2018K000016526 01/03/2018 05:45:00 01/03/2018 10:56:00 01/03/2018 10:56:00 068-624 TO 065-624 - Line Relay'd. Neither end re-closed. LOW PRESSURE ALARM on Tyrone end.
2018L000016528 01/03/2018 09:38:00 01/08/2018 11:17:00 01/08/2018 11:17:00 TC-4515-70 TIE TO TCT-345KV BUS TIE - TC-345 SEC A Lockout
2018K000016588 01/12/2018 01:44:00 01/12/2018 17:25:00 01/12/2018 17:23:00 012-604 TO 012-604 - Line locked out. After we thought we had the problem isolated between the 648-605 to 012-615 the Corydon 012-604 relayed open and closed back. The Serviceman was still by the switches and noticed the line flashing on the customers side of the 012-625 switch. So we opened the 012-604 then had him open and card the 012-625. After that we closed our 012-615 and closed the Corydon 012-604 to test the line to the open Morganfield Ind 648-605. The line held so we put the Corydon to Morganfield 69KV line back to normal leaving the 012-625 open back to the Highland Mine. We called the customer service rep Chuck Lane and left him a message letting him know that mine is offline.
2018K000016589 01/12/2018 07:00:00 03/02/2018 17:00:00 01/12/2018 18:20:00 202-804 TO 009-872 - Transformer Differential
2018K000016602 01/13/2018 16:30:00 01/14/2018 14:45:00 01/14/2018 14:40:00 111-614 TO 193-604 - broken pole, motor vehicle accident
2018L000016768 01/22/2018 01:42:00 01/22/2018 16:11:00 01/22/2018 16:11:00 TC-570 LINE TO 34530 - 4570 Trimble County - Duke/Speed 345KV line relay
2018L000016811 01/26/2018 12:58:00 01/28/2018 17:13:00 01/28/2018 17:13:00 TC-4570 TO 34530-39 - TC-4570 to Duke Speed Relay
2018K000016857 01/31/2018 18:19:00 02/01/2018 04:25:00 02/01/2018 04:25:00 097-814 TO 235-804 - wire down South Paducah substation to first structure
2018K000016907 02/01/2018 07:00:00 02/02/2018 17:00:00 02/02/2018 17:00:00 595-603 TO 595-1F - EKPC line locked out that feeds our 595 MACKVILLE.
2018K000017031 02/12/2018 07:00:00 02/12/2018 15:31:00 02/12/2018 15:31:00 566-603-1 TO 566-603-2 - Squirrel got into low side bus and blew both high side fuses.
2018K000017049 02/14/2018 07:00:00 02/14/2018 14:33:00 02/14/2018 14:30:00 383-JUMPER TO 383-JUMPER - Work on high side fuse. CO 2622
2018L000017062 02/15/2018 05:49:00 02/15/2018 19:51:00 02/15/2018 19:51:00 TT-6619 TO BB-69KV PORT TR - Inspect/repair Line 6619 out in trouble, unknown fault.
2018K000017087 02/16/2018 05:15:00 02/23/2018 14:02:00 02/23/2018 14:02:00 651-615 TO 140-615 - Line locked out, inspect and repair, weather in area - replace 5 broken structures
2018K000017088 02/16/2018 05:54:00 02/16/2018 19:47:00 02/16/2018 19:42:00 100-604 TO 100-604 - Rain in area Earlington North end stayed in and Green River Steel end locked out.
2018L000017096 02/18/2018 13:00:00 02/18/2018 16:54:00 02/18/2018 16:54:00 TC-4511 TO TC-4511-41 TIE - TC-4511 previously opened for Gen #1 outage was found in trouble with 1/3 phases reported in the mechanically closed position. Switching necessary to resolve this problem.